Power Cable

Essential Low Voltage Cables for Safe Power Distribution

Essential Low Voltage Cables for
Safe Power Distribution

LV Cable

Low Voltage Cables are designed for various applications, ensuring efficient and safe electricity distribution in residential, commercial, and industrial settings.

Constructed with durable insulation materials such as PVC and XLPE, our LV Cables withstand harsh environments while maintaining strong electrical performance.

Low Voltage Cables are designed for various applications, ensuring efficient and safe electricity distribution
in residential, commercial, and industrial settings.

Constructed with durable insulation materials such as PVC and XLPE, our LV Cables withstand harsh environments while maintaining strong electrical performance.

0.3/0.6kV Non-Metallic LV Cable

NMD90

NMD90

NMWU

NMWU

NM-B

NM-B

NMD90

0.3kV XLPE Insulated Non-Metallic Dry Cable Aluminum & Copper

Application

to be used for exposed/concealed wiring, residential electrical systems and indoor installations

Standard

ASTM
CSA C22.2 No. 38, No. 48, No. 2556

ASTM | CSA C22.2 No. 38, No. 48, No. 2556

Construction

Aluminum Conductor - Bonding Conductor, XLPE Insulation, PVC Jacket

Copper Conductor - Ground Conductor, PVC/Nylon Insulation, PVC Jacket

Certificate

Canadian Standards Association

NMWU

0.3/0.6kV XLPE Insulated Non-Metallic Underground Cable with FT1 PVC jacket

Application

to be used for exposed/concealed wiring, wet locations, and direct earth burial

Standard

ASTM
CSA C22.2 No. 48, No. 75, No. 2556

ASTM | CSA C22.2 No. 48, No. 75, No. 2556

Specification

Rated at -25°C, 60°C wet/dry
Sun Res

Certificate

Canadian Standards Association

NM-B

0.6kV PVC Insulated Non metallic-Sheathed Cable

Application

to be used for exposed/concealed dry location work, in residential wiring - branch circuits for outlets/switches/other loads, and in air voids of masonry/tile walls

Standard

UL 83, 719 | NFPA 70 | ASTM B-3, B-8

Specification

Federal Specification A-A-59544

Certificate

Underwriters Laboratories Inc.

0.6/1kV General-Purpose LV Cable

RW90

RW90

T90, THHN, THHN-2, TWN75, THW

T90, THHN, THHN-2, TWN75, THW

RW90

0.6kV XLPE Insulated General-purpose Wet Cable Aluminum & Copper

Application

to be used for exposed wiring and raceways (except cable tray) in wet/dry locations

Standard

CSA C22.2 No. 38

Specification

all) -40°C Cold Bend and Impact, Sun Res

Aluminum only) Lead-Free, RoHS compliant

Construction

Copper or Aluminum Conductor - XLPE Insulation

Certificate

Canadian Standards Association

T90, THHN, THHN-2, TWN75, THW

0.6kV Thermoplastic-Insulated Cable

Application

All) Dry, Gasoline & Oil Resistant II condition
T90) Installation in conduit (raceways)
TWN75) Wet/dry locations at ≤ 75°C

Standard

UL 83 | CSA C22.2 No. 75
Canadian Electrical Code | cUL Listed

Specification

CSA FT1-1 Flame Test

Certificate

Canadian Standards Association

CV, CE, TFR-CV, Flexion TFR-CV-WB, HFCO

CV, CE, TFR-CV,
Flexion TFR-CV-WB, HFCO

XHHW-2

XHHW-2

CV, CE

0.6/1kV XLPE Insulated PVC Sheath Cable

Application

to be used for power or lighting circuits in house and building for 0.6/1 kV

Standard

KS C IEC 60502-1

Certificate

Korean Industrial Standard

Safety Certification for Electrical Appliances

TFR-CV

0.6/1kV XLPE Insulated Flame Retardant PVC Sheath Tray Cable

Application

to be used for power or lighting circuits for 0.6/1 kV

Standard

KS C IEC 60502-1, TAIHAN Standard

Certificate

Safety Certification for Electrical Appliances

Flexion TFR-CV-WB

0.6/1kV XLPE Insulated Flame & Water Retardant PVC Sheath Tray Cable

Application

to be used for power or lighting system of 0.6/1 kV

Standard

KS C IEC 60502-1, TAIHAN Standard

Certificate

Safety Certification for Electrical Appliances

HFCO

0.6/1kV XLPE Insulated Halogen Free Polyolefin Sheath Cable

Application

to be used for power or lighting circuits for 0.6/1 kV

Standard

KS C IEC 60502-1

Certificate

Korean Industrial Standard

Korean Eco-Label Certification

XHHW-2

0.6/1kV XLPE Insulated High Heat Wet Cable with Aluminum Conductor

Application

to be used in conduits or recognized raceways for service and feeder wiring, including health care facilities

Standard

UL 44 | NEMA WC-70 | NFPA 70

ASTM B800, B801

Specification

Federal Specification J-C-30B Sunlight resistant

Certificate

Underwriters Laboratories Inc.

0.6/1kV Armored LV Cable

RA90

RA90

AC90

AC90

RA90

0.6kV XLPE Insulated Armor-X® CCW Armored Cable

Application

to be used for wet/dry areas, conduits, ducts, trays, direct burial, aerial use, and Class I, II, III, Division 1 and 2 hazardous locations, including VFD applications

Standard

ASTM B3, B8 | CSA C22.2 No. 123
IEEE 1202 FT4 | UL 44, 1569, 168
ICEA S-58-679, S-95-658

Specification

ICEA T-29-520 (210,000 Btu/hr)

Certificate

Canadian Standards Association

AC90

0.6kV XLPE Insulated Halogen free Metal Clad Armored Cable Aluminum & Copper

Application

to be used for exposed/concealed wiring, cable trays, service entrances, and ceiling fixtures

Standard

CSA C22.2 No. 38, No. 51

Specification

CSA C22.2 No. 2556 FT4-ST1
-40°C Cold Bend and Impact
Halogen free

Construction

Aluminum Conductor - Bonding Conductor, XLPE Insulation, Aluminum Armor

Copper Conductor - Ground Conductor, PVC/Nylon Insulation, Galvanized Steel Interlock Armor

Certificate

Canadian Standards Association

ACWU90

ACWU90

TECK90

TECK90

ACWU90

0.6/1kV XLPE InsulatedMetal Clad Armored Cable Wet Underground with Aluminum

Application

to be used for underground wiring, ladder-type cable trays, service entrances, hazardous locations

Standard

CSA C22.2 No. 38, No. 51, No. 174, No. 2556

Specification

-40°C Cold Bend and Impact

Certificate

Canadian Standards Association

TECK90

0.6/1kV XLPE Insulated Aluminum Interlocked Armored Cable with PVC Jacket

Application

to be used for exposed/concealed wiring, wet/dry conditions, direct burial, and service entrances, resisting damage and corrosion in industrial, commercial, residential, and hazardous settings

Standard

CSA C22.2 No. 131, No. 0.3 (Clause 4, 11.4), C68.10 | NEMA WC7
IEEE 383 & 1202 | ICEA T-29-520, T-30-520, S-66-524

Specification

CSA FT1 & FT4
Class 1 Group A, B, C, D, Division 1 & 2
Class II Group E, F, G, Division 1 & 2

Certificate

Canadian Standards Association

ACWU90

TECK90

ACWU90

0.6/1kV XLPE InsulatedMetal Clad Armored Cable Wet Underground with Aluminum

Application

to be used for underground wiring, ladder-type cable trays, service entrances, hazardous locations

Standard

CSA C22.2 No. 38, No. 51, No. 174, No. 2556

Specification

-40°C Cold Bend and Impact

Certificate

Canadian Standards Association

TECK90

0.6/1kV XLPE Insulated Aluminum Interlocked Armored Cable with PVC Jacket

Application

to be used for exposed/concealed wiring, wet/dry conditions, direct burial, and service entrances, resisting damage and corrosion in industrial, commercial, residential, and hazardous settings

Standard

CSA C22.2 No. 131, No. 0.3 (Clause 4, 11.4), C68.10 | NEMA WC7
IEEE 383 & 1202 | ICEA T-29-520, T-30-520, S-66-524

Specification

CSA FT1 & FT4
Class 1 Group A, B, C, D, Division 1 & 2
Class II Group E, F, G, Division 1 & 2

Certificate

Canadian Standards Association

0.6kV Feeder/Branch Circuit Cable LV Cable

UF-B

Underground Feeder and Branch Circuit Cable

Application

to be used as feeder for outdoor lamp/pump/other load, distribution apparatus, interior wiring in residential/agricultural building, underground/direct burial

Standard

UL 83, 493 | NFPA 70 | ASTM B-3, B-8

Specification

Federal Specification A-A-59544

Certificate

Underwriters Laboratories Inc.

0.6kV Service Entrance LV Cable

USEB90, USEI90

USEB90, USEI90

SEU, SER

SEU, SER

USEB90, USEI90

Underground Service Entrance Cable

Application

to be used for underground distribution, direct burial, or duct installation; sunlight and moisture resistant

Standard

CSA C22.2 No. 52

Certificate

Canadian Standards Association

SEU, SER

XHHW or THHN/THWN Insulated Aluminum Service Entrance Cable

Application

to be used to convey power from service drop to meter base to distribution panel

Standard

ASTM | UL 44, 83, 854

Certificate

Underwriters Laboratories Inc.

0.3/0.6kV Industrial Equipment LV Cable

SOOW

SOOW

SJOOW

SJOOW

SOOW

600V/90°C Heat/Moisture/Oil Resistant Rubber Insulated Flexible Service Cord

Application

to be used for portable tools, equipment, appliances, small motors, and associated machinery with flexibility & durability

Standard

UL 62 | CSA C22.2 No. 49 | MSHA | RoHS-2
NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B

Specification

CSA FT2 Flame Test

Certificate

Canadian Standards Association

Underwriters Laboratories Inc.

SJOOW

300V/105°C Heat/Moisture/Oil Resistant Rubber Insulated Flexible Service Cord

Application

to be used for portable tools, equipment, appliances, small motors, and associated machinery with flexibility & durability

Standard

UL 62 | CSA C22.2 No. 49 | MSHA | RoHS-2
NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B

Specification

CSA FT2 Flame Test

Certificate

Canadian Standards Association

Underwriters Laboratories Inc.

Talk to our Specialist.

Our team will get in touch with you shortly. We are ready to discuss your needs and any questions you might have in detail.

Talk to our Specialist.

Our team will get in touch with you shortly. We are ready to discuss your needs and any questions you might have in detail.

Talk to our Specialist.

Our team will get in touch with you shortly. We are ready to discuss your needs and any questions you might have in detail.

Talk to our Specialist.

Our team will get in touch with you shortly.
We are ready to discuss your needs and any questions
you might have in detail.