Power Cable
LV Cable
0.3/0.6kV Non-Metallic LV Cable
NMD90
0.3kV XLPE Insulated Non-Metallic Dry Cable Aluminum & Copper
Application
to be used for exposed/concealed wiring, residential electrical systems and indoor installations
Standard
Construction
Aluminum Conductor - Bonding Conductor, XLPE Insulation, PVC Jacket
Copper Conductor - Ground Conductor, PVC/Nylon Insulation, PVC Jacket
Certificate
Canadian Standards Association
NMWU
0.3/0.6kV XLPE Insulated Non-Metallic Underground Cable with FT1 PVC jacket
Application
to be used for exposed/concealed wiring, wet locations, and direct earth burial
Standard
Specification
Rated at -25°C, 60°C wet/dry
Sun Res
Certificate
Canadian Standards Association
NM-B
0.6kV PVC Insulated Non metallic-Sheathed Cable
Application
to be used for exposed/concealed dry location work, in residential wiring - branch circuits for outlets/switches/other loads, and in air voids of masonry/tile walls
Standard
UL 83, 719 | NFPA 70 | ASTM B-3, B-8
Specification
Federal Specification A-A-59544
Certificate
Underwriters Laboratories Inc.
0.6/1kV General-Purpose LV Cable
RW90
0.6kV XLPE Insulated General-purpose Wet Cable Aluminum & Copper
Application
to be used for exposed wiring and raceways (except cable tray) in wet/dry locations
Standard
CSA C22.2 No. 38
Specification
all) -40°C Cold Bend and Impact, Sun Res
Aluminum only) Lead-Free, RoHS compliant
Construction
Copper or Aluminum Conductor - XLPE Insulation
Certificate
Canadian Standards Association
T90, THHN, THHN-2, TWN75, THW
0.6kV Thermoplastic-Insulated Cable
Application
All) Dry, Gasoline & Oil Resistant II condition
T90) Installation in conduit (raceways)
TWN75) Wet/dry locations at ≤ 75°C
Standard
UL 83 | CSA C22.2 No. 75
Canadian Electrical Code | cUL Listed
Specification
CSA FT1-1 Flame Test
Certificate
Canadian Standards Association
CV, CE
0.6/1kV XLPE Insulated PVC Sheath Cable
Application
to be used for power or lighting circuits in house and building for 0.6/1 kV
Standard
KS C IEC 60502-1
Certificate
Korean Industrial Standard
Safety Certification for Electrical Appliances
TFR-CV
0.6/1kV XLPE Insulated Flame Retardant PVC Sheath Tray Cable
Application
to be used for power or lighting circuits for 0.6/1 kV
Standard
KS C IEC 60502-1, TAIHAN Standard
Certificate
Safety Certification for Electrical Appliances
Flexion TFR-CV-WB
0.6/1kV XLPE Insulated Flame & Water Retardant PVC Sheath Tray Cable
Application
to be used for power or lighting system of 0.6/1 kV
Standard
KS C IEC 60502-1, TAIHAN Standard
Certificate
Safety Certification for Electrical Appliances
HFCO
0.6/1kV XLPE Insulated Halogen Free Polyolefin Sheath Cable
Application
to be used for power or lighting circuits for 0.6/1 kV
Standard
KS C IEC 60502-1
Certificate
Korean Industrial Standard
Korean Eco-Label Certification
XHHW-2
0.6/1kV XLPE Insulated High Heat Wet Cable with Aluminum Conductor
Application
to be used in conduits or recognized raceways for service and feeder wiring, including health care facilities
Standard
UL 44 | NEMA WC-70 | NFPA 70 ASTM B800, B801
Specification
Federal Specification J-C-30B Sunlight resistant
Certificate
Underwriters Laboratories Inc.
0.6/1kV Armored LV Cable
RA90
0.6kV XLPE Insulated Armor-X® CCW Armored Cable
Application
to be used for wet/dry areas, conduits, ducts, trays, direct burial, aerial use, and Class I, II, III, Division 1 and 2 hazardous locations, including VFD applications
Standard
ASTM B3, B8 | CSA C22.2 No. 123
IEEE 1202 FT4 | UL 44, 1569, 168
ICEA S-58-679, S-95-658
Specification
ICEA T-29-520 (210,000 Btu/hr)
Certificate
Canadian Standards Association
AC90
0.6kV XLPE Insulated Halogen free Metal Clad Armored Cable Aluminum & Copper
Application
to be used for exposed/concealed wiring, cable trays, service entrances, and ceiling fixtures
Standard
CSA C22.2 No. 38, No. 51
Specification
CSA C22.2 No. 2556 FT4-ST1
-40°C Cold Bend and Impact
Halogen free
Construction
Aluminum Conductor - Bonding Conductor, XLPE Insulation, Aluminum Armor
Copper Conductor - Ground Conductor, PVC/Nylon Insulation, Galvanized Steel Interlock Armor
Certificate
Canadian Standards Association
0.6kV Feeder/Branch Circuit Cable LV Cable
UF-B
Underground Feeder and Branch Circuit Cable
Application
to be used as feeder for outdoor lamp/pump/other load, distribution apparatus, interior wiring in residential/agricultural building, underground/direct burial
Standard
UL 83, 493 | NFPA 70 | ASTM B-3, B-8
Specification
Federal Specification A-A-59544
Certificate
Underwriters Laboratories Inc.
0.6kV Service Entrance LV Cable
USEB90, USEI90
Underground Service Entrance Cable
Application
to be used for underground distribution, direct burial, or duct installation; sunlight and moisture resistant
Standard
CSA C22.2 No. 52
Certificate
Canadian Standards Association
SEU, SER
XHHW or THHN/THWN Insulated Aluminum Service Entrance Cable
Application
to be used to convey power from service drop to meter base to distribution panel
Standard
ASTM | UL 44, 83, 854
Certificate
Underwriters Laboratories Inc.
0.3/0.6kV Industrial Equipment LV Cable
SOOW
600V/90°C Heat/Moisture/Oil Resistant Rubber Insulated Flexible Service Cord
Application
to be used for portable tools, equipment, appliances, small motors, and associated machinery with flexibility & durability
Standard
UL 62 | CSA C22.2 No. 49 | MSHA | RoHS-2
NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B
Specification
CSA FT2 Flame Test
Certificate
Canadian Standards Association
Underwriters Laboratories Inc.
SJOOW
300V/105°C Heat/Moisture/Oil Resistant Rubber Insulated Flexible Service Cord
Application
to be used for portable tools, equipment, appliances, small motors, and associated machinery with flexibility & durability
Standard
UL 62 | CSA C22.2 No. 49 | MSHA | RoHS-2
NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B
Specification
CSA FT2 Flame Test
Certificate
Canadian Standards Association
Underwriters Laboratories Inc.