Power Cable

Tailored Solutions for Unique Power Needs

Power Cable

Tailored Solutions for Unique Power Needs

Utility/Specialized Cable

Utility/Specialized Cables cater to specific industry requirements, offering exceptional performance for a wide range of applications.

Our selection is engineered with advanced insulation technologies, ensuring durability and safety in demanding conditions.

Bare Conductor

ACSR, ACAR

ACSR, ACAR

AAAC

AAAC

ACSR

Aluminum Conductor Steel Reinforced

Application

to be used for river crossings, overhead ground wires, and HV/EHV lines requiring extra-long spans

Standard

BS 215-2, EN 50182 | IEC 61089
ASTM B 231/B 231M | DIN 48201

AAAC

All Aluminium Alloy Conductor

Application

to be used for aerial circuits and T&D lines, requiring higher strength than AAC and better corrosion resistance than ACSR

Standard

BS 3242, EN 50182 | IEC 61089
ASTM B 399 | DIN 48201

ACAR

Aluminum Conductor Alloy Reinforced

Application

to be used for T&D projects where AAC conductors lack strength, and AAAC/ACSR conductors are unnecessary or unsuitable

Solar Cable

RHH, RHW, USE-2

RHH, RHW, USE-2

RPV, RPVU90

RPV, RPVU90

UL4703

UL4703

RHH, RHW, USE-2

0.6kV XLPE Insulated Aluminum High Heat, Heat/Water Resistant, Underground Service Entrance Cable

Application

to be used for connecting mobile homes to electricity supply with permanent wiring, suitable for direct burial

Standard

ASTM B800, B801, B836 | NFPA 70
UL 44, 854

Specification

Federal Specification A-A-59544

Certificate

Underwriters Laboratories Inc.

RPV, RPVU90

1kV/2kV XLPE Insulated Photovoltaic Cable

Application

to be used for exposed wiring and raceways (except cable tray) in wet/dry areas, interconnection of solar photovoltaic systems, and direct earth burial

Standard

CSA C22.2 No. 38, No. 271 | ASTM B3

CSA C22.2 No. 38, No. 271
ASTM B3

Specification

-40°C Cold Bend and Impact
Sunlight Resistant

Certificate

Canadian Standards Association

PV Cable UL4703

0.6kV/1kV/2kV XLPE Insulated Photovoltaic Cable Aluminum & Copper

Application

to be used for solar industry needs, including module junction box connections and cable routing in balance of system (BOS) integration

Standard

UL 44, 854, 4703

Certificate

Underwriters Laboratories Inc.

Optional

Voltage

0.6kV, 1kV, 2kV

Temperature

90°C(wet), 105°C, 125°C, 150°C(dry)

Conductor Size

12AWG - 2000kcmil stranded Al/CCA,
18 AWG - 2000 kcmil
stranded Cu/TCC

H1Z2Z2-K

H1Z2Z2-K

MOBILE HOME FEEDER

MOBILE HOME FEEDER

H1Z2Z2-K

1kV Low Smoke-Zero Halogen EBXL Insulated Flexible Cable

Application

to be used for photovoltaic interconnections like solar panel arrays in fixed internal/external installations, in conduits/systems

Standard

IEC 60332-1-2, 60754-1/2, 61034-1/2 | ISO 4892-1/3
TÜV 2 PfG 1169/08.2007 | EN 50267-2-2, 50288-3-7, 50395, 50396, 50618, 60068-2-78, 60811-403

IEC 60332-1-2, 60754-1/2, 61034-1/2 | ISO 4892-1/3
TÜV 2 PfG 1169/08.2007
EN 50267-2-2, 50288-3-7, 50395, 50396, 50618, 60068-2-78, 60811-403

Specification

Water Resistant to Ad8
Impact Tested

MOBILE HOME FEEDER

0.6kV XLPE Insulated Aluminum Mobile Home Feeder

Application

to be used for connecting mobile homes to electricity supply with permanent wiring, suitable for direct burial

Standard

ASTM B800, B801, B836 | NFPA 70
UL 44, 854 | NEMA WC-70

Specification

Federal Specification A-A-59544

Certificate

Underwriters Laboratories Inc.

Fire-Resistant Cable

TFR-8, HF-NFR-8

TFR-8,
HF-NFR-8

TFR-3, HF-NFR-3

TFR-3,
HF-NFR-3

RC90

RC90

TFR-8, HF-NFR-8

0.6/1kV Fire Retardant Cable for Fire fighting
Halogen free Polyolefin sheathed Fire-resistant Cable for Fire Fighting

Application

to be used for emergency power or control circuits of fire fighting equipment for 0.6/1kV

Standard

KS C IEC 60502-1, TAlHAN Standard

Certificate

Safety Certification for Electrical Appliances

TFR-3, HF-NFR-3

0.6/1kV Tray Heat-resistant Cable for Fire fighting
Halogen free Polyolefin sheathed Heat-resistant Cable for Fire Fighting

0.6/1kV Tray Heat-resistant Cable for Fire fighting Halogen free Polyolefin sheathed Heat-resistant Cable for Fire Fighting

Application

to be used for power distribution line of emergency facility like speaker, lighting, and alarm for 0.6/1kV

Standard

KS C IEC 60502-1, TAlHAN Standard

Certificate

Safety Certification for Electrical Appliances

RC90

Low Smoke-Zero Halogen Armored Fire-Resistant Copper Cable

Application

to be used for fire pumps, emergency systems, exhaust/pressurization fans, fireman’s elevators, fire alarm, egress elevators, emergency device activation, lighting & signage, ATS

Standard

CSA C22.2 No. 123
ULC S139 2-Hour Fire Rating
Electrical Circuit Integrity System #120
Meets NFPA 130, 502

Specification

Wet Location Rating: 90°C
ULC FHIT7 60/60A, 120/120A

Certificate

Canadian Standards Association

Construction

Single conductor / Multi-conductor

Fire-Resistant Cable

TFR-8, HF-NFR-8

TFR-3, HF-NFR-3

RC90

TFR-8, HF-NFR-8

0.6/1kV Fire Retardant Cable for Fire fighting
Halogen free Polyolefin sheathed Fire-resistant Cable for Fire Fighting

Application

to be used for emergency power or control circuits of fire fighting equipment for 0.6/1kV

Standard

KS C IEC 60502-1, TAlHAN Standard

Certificate

Safety Certification for Electrical Appliances

TFR-3, HF-NFR-3

0.6/1kV Tray Heat-resistant Cable for Fire fighting Halogen free Polyolefin sheathed Heat-resistant Cable for Fire Fighting

Application

to be used for power distribution line of emergency facility like speaker, lighting, and alarm for 0.6/1kV

Standard

KS C IEC 60502-1, TAlHAN Standard

Certificate

Safety Certification for Electrical Appliances

RC90

Low Smoke-Zero Halogen Armored Fire-Resistant Copper Cable

Application

to be used for fire pumps, emergency systems, exhaust/pressurization fans, fireman’s elevators, fire alarm, egress elevators, emergency device activation, lighting & signage, ATS

Standard

CSA C22.2 No. 123
ULC S139 2-Hour Fire Rating
Electrical Circuit Integrity System #120
Meets NFPA 130, 502

Specification

Wet Location Rating: 90°C
ULC FHIT7 60/60A, 120/120A

Certificate

Canadian Standards Association

Construction

Single conductor / Multi-conductor

Underground Cable

NMWU

NMWU

UF-B

UF-B

USEB90, USEI90

USEB90, USEI90

NMWU

0.3/0.6kV XLPE Insulated Non-Metallic Underground Cable with FT1 PVC jacket

Application

to be used for exposed/concealed wiring, wet locations, and direct earth burial

Standard

ASTM
CSA C22.2 No. 48, No. 75, No. 2556

Specification

Rated at -25°C, 60°C wet/dry
Sun Res

Certificate

Canadian Standards Association

UF-B

0.6kV Underground Feeder and Branch Circuit Cable

Application

to be used as feeder for outdoor lamp/pump/other load, distribution apparatus, interior wiring in residential/agricultural building, underground/direct burial

Standard

UL 83, 493 | NFPA 70 | ASTM B-3, B-8

UL 83, 493 | NFPA 70
ASTM B-3, B-8

Specification

Federal Specification A-A-59544

Certificate

Underwriters Laboratories Inc.

USEB90, USEI90

0.6kV Underground Service Entrance Cable

Application

to be used for underground distribution, direct burial, or duct installation; sunlight and moisture resistant

Standard

CSA C22.2 No. 52

Certificate

Canadian Standards Association

ACWU90

ACWU90

MV-90, MV-105

MV-90, MV-105

ACWU90

0.6kV/1kV Metal Clad Armored Cable Wet Underground with Aluminum

Application

to be used for underground wiring, ladder-type cable trays, service entrances, hazardous locations

Standard

CSA C22.2 No. 38, No. 51, No. 174, No. 2556

Specification

-40°C Cold Bend and Impact

Certificate

Canadian Standards Association

MV-90, MV-105

5-46kV URD Cable Aluminum & Copper

Application

to be used for underground distribution in conduits, wet/dry areas, direct burial, ducts, and sunlight exposure

Standard

UL 1072 | CSA C68.5 | AEIC CS8
ICEA S-94-649

Certificate

Underwriters Laboratories Inc.

Optional

Voltage

5kV, 8kV, 15kV, 25kV, 28kV, 35kV, 46kV

Conductor

AA-8000 Series

Screen

Copper Tape Shield

Insulation

TR-XLPE, EPR (UL)

Insulation Level

100%, 133%, 173%

Neutral

Full, 1/3, 1/6, 1/8, 1/12

Jacket

XLPE (UL), PVC

Industrial Equipment Cable

SOOW

SOOW

SJOOW

SJOOW

H01N2-D

H01N2-D

SOOW

600V/90°C Heat/Moisture/Oil Resistant Rubber Insulated Flexible Service Cord

Application

to be used for portable tools, equipment, appliances, small motors, and associated machinery with flexibility & durability

Standard

UL 62 | CSA C22.2 No. 49 | MSHA | RoHS-2
NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B

UL 62 | CSA C22.2 No. 49
MSHA | RoHS-2

NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B

Specification

CSA FT2 Flame Test

Certificate

Canadian Standards Association

Underwriters Laboratories Inc.

SJOOW

300V/105°C Heat/Moisture/Oil Resistant Rubber Insulated Flexible Service Cord

Application

to be used for portable tools, equipment, appliances, small motors, and associated machinery with flexibility & durability

Standard

UL 62 | CSA C22.2 No. 49 | MSHA | RoHS-2
NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B

UL 62 | CSA C22.2 No. 49
MSHA | RoHS-2

NEC 400, 501.140 Class I Division 2
Federal and Military Specification JC-580B

Specification

CSA FT2 Flame Test

Certificate

Canadian Standards Association

Underwriters Laboratories Inc.

H01N2-D

Welding Cable

Application

to be used to power welding equipment for steel construction industry - metal sheets, tubes, and other steel components

Standard

EN 50525-2-81 | HD 22.6 | IEC 60245

EN 50525-2-81 | HD 22.6
IEC 60245

Certificate

Underwriters Laboratories Inc.

Type W

Type W

DLO

DLO

Type W

EPDM Insulated Heavy-duty Flexible Mining Cable

Application

to be used for light/medium-duty application (mining, portable equipment, submersible pumps), resistant to sun/oil/cold conditions

Standard

ASTM B3, B172 | UL 1650 | RoHS-2

Specification

MSHA Approved

Certificate

Canadian Standards Association

DLO

2kV Thermoset Insulated Heavy-Duty Flexible Cable,
Resistant to Oil/Heat/Flame/Abrasion/Sun

Application

to be used to drilling rigs, railroad/transit car wiring, mining/industrial equipment, flexible motor leads, wind turbine applications in wet/dry areas, conduits, ducts, troughs, trays

Standard

ICEA S-95-658 / NEMA WC-70
UL 44, 1685 | ASTM B-33, B-172

Certificate

Underwriters Laboratories Inc.

Type G

Type G

Type G-GC

Type G-GC

Type SHD-GC

Type SHD-GC

Type G

EPDM Insulated Heavy-duty Flexible Mining Cable

Application

to be used for heavy-duty applications requiring grounding (mining, submersible pumps, portable equipment, marine use), resistant to sun/oil/cold conditions

Standard

ASTM B3, B172 | UL 1650 | RoHS-2

Specification

MSHA Approved

Certificate

Canadian Standards Association

Type G-GC

2kV EPDM Insulated Heavy-duty Flexible Mining Cable with Ground Check

Application

to be used for heavy-duty applications requiring grounding (mining, submersible pumps, portable equipment, marine use), resistant to sun/oil/cold conditions

Standard

ICEA S-75-381 / NEMA WC-58
ASTM B-33, B-172 | MSHA Listed
CSA C22.2 No. 96

Certificate

Canadian Standards Association

Underwriters Laboratories Inc.

Type SHD-GC

2/5/8/15/25kV EPR Insulated Super Heavy Duty Flexible Mining Cable with Ground Check

Application

to be for mobile/reeling/stationary mining equipment, continuous mining machines, drills, shovels, cranes, and marine shore-to-ship power supplies, requiring flexibility and maximum protection

Standard

ICEA S-75-381 | ASTM B-33, B-172
CSA C22.2 No. 96

Specification

MSHA Approved
-50°C Cold Bend and Impact

Certificate

Canadian Standards Association

Underwriters Laboratories Inc.

Talk to our Specialist.

Our team will get in touch with you shortly. We are ready to discuss your needs and any questions you might have in detail.

Talk to our Specialist.

Our team will get in touch with you shortly.
We are ready to discuss your needs and any questions
you might have in detail.

Talk to our Specialist.

Our team will get in touch with you shortly. We are ready to discuss your needs and any questions you might have in detail.

Talk to our Specialist.

Our team will get in touch with you shortly. We are ready to discuss your needs and any questions you might have in detail.